Angry AZC: No Blower Motor 40A Fuse Good

I was driving the other day with the heat on and the blower motor just shut off. I can still feel the heat but there is no fan to blow it out
I have a limited so it has the Auto Zone Control

1. Checked the 40A Fuse and it is good
2. I can hear the blend doors move when I change the position of the selector knob
3. I want to take a look at the problem myself as I consider myself fairly handy with things

From the web I think the blower motor is behind the glove box and it looks fairly easy to get to.

I also know about the burned connector problems. So my questions are does anyone have more trouble shooting tips and what is the exact procedure to get to the motor and dismantle the glove box?
__________________

__________________
Reply With Quote
  #2  
Old 03-01-2014, 09:11 PM
hoffmanestates's Avatar
Senior Member
 
Join Date: Nov 2011
Posts: 1,070
Thanks: 1
Thanked 5 Times in 5 Posts
Rep Power: 2544
hoffmanestates has a reputation beyond reputehoffmanestates has a reputation beyond reputehoffmanestates has a reputation beyond reputehoffmanestates has a reputation beyond reputehoffmanestates has a reputation beyond reputehoffmanestates has a reputation beyond reputehoffmanestates has a reputation beyond reputehoffmanestates has a reputation beyond reputehoffmanestates has a reputation beyond reputehoffmanestates has a reputation beyond reputehoffmanestates has a reputation beyond repute
there ya go, remove motor and check for power/ground if those good supply own power ground to motor if motor bad replace. IF no power/ground to plug of motor replace resistor or control panel which ever it is

Sent from my LG-P999 using Tapatalk 2
__________________

__________________
Reply With Quote
  #3  
Old 03-02-2014, 07:48 AM
Frango100's Avatar
Premium Member

My Jeep: 2004 4.7L WJ
 
Join Date: Dec 2009
Location: Brazil
Posts: 5,309
Thanks: 9
Thanked 131 Times in 124 Posts
Rep Power: 526360
Frango100 has a reputation beyond reputeFrango100 has a reputation beyond reputeFrango100 has a reputation beyond reputeFrango100 has a reputation beyond reputeFrango100 has a reputation beyond reputeFrango100 has a reputation beyond reputeFrango100 has a reputation beyond reputeFrango100 has a reputation beyond reputeFrango100 has a reputation beyond reputeFrango100 has a reputation beyond reputeFrango100 has a reputation beyond repute
Re: AZC: No Blower Motor 40A Fuse Good

You won´t have to do anything with the glove box, the blower motor is accessable from below the passengers footwell. Just three screws and it will come down. The blower motor controller sits just next to the blower motor, indeed check the connector on it, because most of the times its just melted away. In that case you could buy a new connector, or just solder the wires directly to the controller board. See here for a writeup on this: Replacing Blower Motor Resister Wiring.
It is ofcourse possible that the controller itself is the problem or in remote cases the blower motor itself. You can measure directly on the blower motor connector between points 1 and 2 to see if you have voltage there, see attached schematic.
Attached Files
File Type: pdf AZC.pdf (148.5 KB, 2 views)
__________________
Frank

JEEP Grand Cherokee 4.7 Lmtd 2004
HID 8000K in low and fog / Quad Squad member
KYB Gas-a-Just shocks / Pirelli Scorpion ATR 245/65/17 - Transgo reprogramming shiftkit.

VW Beetle 2.0 TSI 2013
My new toy
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Blower motor HELP Boomer914 Troubleshooting/Problems 7 12-18-2013 10:21 AM
Noise from blower motor roddaz Troubleshooting/Problems 1 11-28-2012 05:41 PM
How To Remove Blower Motor 05+ WK GratefulDeadWK Troubleshooting/Problems 2 09-06-2012 09:38 AM
Blowing Blower Motor Fuses gemspeaker Troubleshooting/Problems 7 05-28-2011 05:37 PM
Blower motor issues peepersjeepers Troubleshooting/Problems Discussion 3 02-14-2011 10:39 AM

Powered by vBadvanced CMPS v3.2.3

All times are GMT -5. The time now is 09:50 PM.


Powered by vBulletin® Version 3.8.8 Beta 4
Copyright ©2000 - 2014, vBulletin Solutions, Inc.
Copyright 2012 - JeepGarage.Org
The Jeep Grand Cherokee Owners Community

JeepGarage.org is in no way associated with or endorsed by Chrysler Group LLC.