  #13  
Old 09-04-2011, 09:20 PM
Member
 
Join Date: May 2011
Posts: 99
Thanks: 0
Thanked 0 Times in 0 Posts
Rep Power: 1320
UrbanAssaultJeep is on a distinguished road
I checked the plug in the third picture and was unable to remove the plug and I assume it's melted together because where the red wire goes in, it is black/burnt in color. When I had removed blower to test it, it turned snug by hand.

So if the plug does not remove from controller, do I also need a new controller, repair kit for harness, and since the blower motor doesn't easily spin, should I also replace that?
__________________

__________________
01 GC Limited - Mods: V-LEDS Interior & Ext | Shorty Antenna | 20" Black SRT8 Repo Wheels | Tint: 5% Strip, 15% Fronts, 15% over rear privacy glass | Kolak 3" Exhaust | Hertz HSK 165 Components F&R | Hertz Mille Subwoofer | Rockford Amps
Reply With Quote
  #14  
Old 09-04-2011, 10:05 PM
Frango100's Avatar
Premium Member

My Jeep: 2004 4.7L WJ
 
Join Date: Dec 2009
Location: Brazil
Posts: 4,900
Thanks: 9
Thanked 91 Times in 86 Posts
Rep Power: 525849
Frango100 has a reputation beyond reputeFrango100 has a reputation beyond reputeFrango100 has a reputation beyond reputeFrango100 has a reputation beyond reputeFrango100 has a reputation beyond reputeFrango100 has a reputation beyond reputeFrango100 has a reputation beyond reputeFrango100 has a reputation beyond reputeFrango100 has a reputation beyond reputeFrango100 has a reputation beyond reputeFrango100 has a reputation beyond repute
Re: Blower Motor Not Blowing Air

You didnīt mention before that the blower motor isnīt turning that well. The higher current needed to turn a damaged blower motor, could cause the connector to melt, when the contacts inside the connector have some resistance.
So yeah, you probably have to change the blower motor as well. I have no idea about the price of a new controller, but would try again to remove the connector, maybe with some tools. If it breaks, you had to change it anyway.
__________________

__________________
Frank

JEEP Grand Cherokee 4.7 Lmtd 2004
HID 8000K in low and fog / Quad Squad member
KYB Gas-a-Just shocks / Pirelli Scorpion ATR 245/65/17 - Transgo reprogramming shiftkit.

VW Beetle 2.0 TSI 2013
My new toy
Reply With Quote
  #15  
Old 09-05-2011, 01:59 AM
2005JGC's Avatar
Senior Member


My Jeep: 2005 4.7L WK
 
Join Date: Nov 2010
Location: Portland, OR
Posts: 2,751
Thanks: 51
Thanked 69 Times in 58 Posts
Rep Power: 1652969
2005JGC has a reputation beyond repute2005JGC has a reputation beyond repute2005JGC has a reputation beyond repute2005JGC has a reputation beyond repute2005JGC has a reputation beyond repute2005JGC has a reputation beyond repute2005JGC has a reputation beyond repute2005JGC has a reputation beyond repute2005JGC has a reputation beyond repute2005JGC has a reputation beyond repute2005JGC has a reputation beyond repute
Re: Blower Motor Not Blowing Air

Yep, just like the resistor on the standard hvac boxes this is the culprit on the dual zone typically. Mopar does sell a terminal repair kit that I HIGHLY suggest you get with the new controller. (Mopar PN 05102406AA)

If you turn your hvac knob on then grab this 3 wire connector the likely hood of it cutting in and out (or just turning on at least for a little while) is pretty good. VERY common.
__________________
2005 Jeep Grand Cherokee - Gone but not forgotten!

Reply With Quote
  #16  
Old 09-09-2011, 08:15 PM
Member
 
Join Date: May 2011
Posts: 99
Thanks: 0
Thanked 0 Times in 0 Posts
Rep Power: 1320
UrbanAssaultJeep is on a distinguished road
Re: Blower Motor Not Blowing Air

Quote:
Originally Posted by 2005JGC View Post
Yep, just like the resistor on the standard hvac boxes this is the culprit on the dual zone typically. Mopar does sell a terminal repair kit that I HIGHLY suggest you get with the new controller. (Mopar PN 05102406AA)
Replaced harness with your mopar PN, and problem is now fixed. Would also replace blower, but trying to sell the WJ for a newer model.
__________________

__________________
01 GC Limited - Mods: V-LEDS Interior & Ext | Shorty Antenna | 20" Black SRT8 Repo Wheels | Tint: 5% Strip, 15% Fronts, 15% over rear privacy glass | Kolak 3" Exhaust | Hertz HSK 165 Components F&R | Hertz Mille Subwoofer | Rockford Amps
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Blowing Blower Motor Fuses gemspeaker Troubleshooting/Problems 7 05-28-2011 05:37 PM
Heater blower motor resistor? TimmyB Troubleshooting/Problems Discussion 25 03-30-2011 12:59 PM
Blower motor issues peepersjeepers Troubleshooting/Problems Discussion 3 02-14-2011 10:39 AM
Blower Motor connector repair karen Tech Tips DIY/How To 10 01-20-2011 02:59 PM
Wierd (?) blower motor issue Delta Dog Troubleshooting/Problems 9 10-28-2010 06:54 AM

Powered by vBadvanced CMPS v3.2.3

All times are GMT -5. The time now is 02:54 PM.


Powered by vBulletin® Version 3.8.8 Beta 4
Copyright ©2000 - 2014, vBulletin Solutions, Inc.
Copyright 2012 - JeepGarage.Org
The Jeep Grand Cherokee Owners Community